AC Capacitor Replacement (2024)

Jump to Specific Section

  • Safety Precautions for Replacing AC Capacitors
  • How to Find the Right Replacement Capacitor
  • AC Capacitor Replacement Procedure
  • More Products. More Tools. More Perks.

1

Safety Precautions for Replacing AC Capacitors

AC Capacitor Replacement (1)

AC capacitors can be dangerous if not handled correctly. However, preparation and proper safety equipment ensure the process is safe and efficient for HVAC technicians.

You will need to following equipment to safely replace an AC capacitor:

  • Safety glasses
  • Electrician’s work gloves
  • Multimeter
  • Insulated tools, including a screwdriver and needle nose pliers
  • A set of small jumper cables with a resistor

Before troubleshooting or replacing a capacitor, make sure the power supply to the AC unit is shut off completely. Then locate the side panel on the AC unit and remove it to continue working.

  • Turn the thermostat off.
  • Turn off the main power supply to the breaker connected to the AC unit. This is typically close to the AC compressor.
  • Remove the circuit breaker from the breaker box and set it aside.
  • Examine the capacitor for any signs of damage or malfunction. Broken capacitors typically bulge up from the top and their terminals point in different directions.
  • Set the capacitor on a flat surface to ensure it is not bulging from the bottom. If the capacitor rocks back and forth, it is time to replace the capacitor.

Capacitors must be discharged before testing and troubleshooting can begin. There are two common methods of discharging capacitors. One requires an insulated metal tool like a screwdriver, and the other requires a set of jumper cables attached to a resistor.

Make a note of where each wire is connected on the capacitor. Every capacitor has a common (C) terminal. Single capacitors also have either a condenser fan (FAN) or a hermetically sealed compressor (HERM) terminal. Dual capacitors have all three of these terminals.

  • The screwdriver method requires connecting the screwdriver to the C terminal and either the FAN or HERM terminal. If there is a charge, the capacitor will release it, and the screwdriver will vibrate quickly with a buzzing sound. Be sure to repeat this process between the C terminal and either the FAN or HERM terminals if you are working with a dual capacitor.
  • The jumper cable method requires a pair of jumper cables that are connected to a resistor. Connect one jumper to the C terminal, and the other to either the FAN or HERM terminal. Any charge in the capacitor will discharge through to the resistor.

If possible, discharge the capacitor before removing any wires. This provides the most safety when removing the capacitor from the AC unit. However, the wire fittings may obstruct a clear path between the terminals for a screwdriver to connect. If you do not have jumper cables and a resistor, use needle nose pliers to detach the wires and clear the way for your screwdriver.

Once the capacitor is discharged, you can test its capacitance and resistance with a multimeter. First, set your multimeter to the capacitance function.

  • To test the condenser fan section of the capacitor, attach one of the multimeter jumpers to the condenser fan (FAN) terminal, and the other to the common (C) terminal.
  • To test the compressor fan section of the capacitor, attach one of the multimeter jumpers to the hermetically-sealed compressor (HERM) terminal, and the other to the common (C) terminal.
  • For both sections, wait for the capacitance reading to appear on the screen. A good reading will display the microfarads within 10% of the amount specified on the label.

Another option for testing capacitors is by measuring its resistance. An analog multimeter is recommended for this because digital multimeters do not always show the changes in ohms that indicate a working capacitor. Set your multimeter to the resistance (ohms) function.

  • Attach one of the jumpers to the C terminal and the other on the FAN terminal.
  • The needle should jump up and then fall back down to infinity ohms. If it does not, the capacitor may need to be replaced.
  • Reverse the jumpers and look for the same response from the needle.
  • Repeat this process between the C and HERM fan terminals.
  • Attach one of the jumpers to the C terminal, and touch the other to the side of the capacitor. If the reading indicates continuity by showing very low or zero ohms, the capacitor must be replaced.

Pro Tip: For the most accurate assessments, bring both digital and analog multimeters to the job site.

2

How to Find the Right Replacement Capacitor

AC Capacitor Replacement (2)

A replacement capacitor must meet the specifications listed on the old capacitor. The label will contain the information required to ensure a new part is compatible with the AC unit. Some capacitors are made to fit many types of units, but most are manufactured for a specific purpose. When selecting a new capacitor to replace a broken one, ensure the following specifications match:

  • Capacitance: Measured in microfarads, (µF or MFD) the capacitance refers to how much charge the capacitor can hold.
  • Voltage: Capacitors are usually rated for both 370 volts and 440 volts. You can use a new capacitor with a higher voltage than the original, but never choose one that has a lower voltage rating than the system voltage.
  • Frequency: AC capacitors are typically rated for 50 and 60 hertz. If the only accessible capacitors are rated for just one, ensure it is rated for the same frequency as the original capacitor.
  • Terminal Types: Capacitor terminals include one to four metal tabs. Make sure that your replacement capacitor has terminals with enough tabs to support all necessary connections to reassemble the AC unit.
  • Case Shape: Capacitors will typically resemble a round cylinder or an oval shape. If the capacitance, voltage and frequency are consistent with the old capacitor, the new capacitor can be of either shape.

When using capacitors with more than three terminals, follow the instructions included with the capacitor to ensure you connect the wires properly for an AC unit. For some units, two of the terminals may need to be connected by a wire in addition to the AC unit itself.

Pro Tip: The average AC capacitor lasts about 20 years. However, prolonged humidity and hot weather can add wear and tear. In areas like Florida or Texas, you can expect to replace a capacitor after about 15 years.

3

AC Capacitor Replacement Procedure

AC Capacitor Replacement (3)

A capacitor must be discharged before it can be replaced to ensure safe disposal. Once the old capacitor is discharged, continue removing it from the AC unit and prepare to install the new one:

  • Disconnect the wires from the capacitor.
  • Use a multimeter to test the capacitance of each terminal. Connect one prong to the C terminal and the other to either the FAN or HERM terminal. A broken capacitor will read very low compared to the capacitance printed on its label. Dual capacitors must be replaced even if only one of these terminals is not displaying the proper capacitance.
  • Unscrew the metal strap holding the capacitor in place and remove the capacitor from the AC unit.
  • Take your new capacitor out of the box and affix the metal strap around it so that it is affixed to the AC unit.
  • Attach each wire to the new capacitor in the same configuration as the old capacitor.
  • Return the breaker to the breaker box, turn the main power on, and turn on the thermostat
  • Ensure the AC unit is working normally again. If you replaced the capacitor properly and the AC unit is still running slow or not dispensing cool air, there may be another problem.

Pro Tip: If the metal strap from the old capacitor does not fit the new capacitor, cut some pipe hanger strapto length. Screw it into the same hole where the original strap was connected.

4

More Products. More Tools. More Perks.

AC Capacitor Replacement (4)

Be more competitive and boost your bottom line with Pro Xtra, The Home Depot’s free loyalty program built for Pros. Sign up today to access the enhanced Pro Online Experience, built with the online business tools and time-saving features Pros need.

Earn rewards, like Pro Xtra Dollars or a Tool Rental Perk just for shopping at The Home Depot. Plus, get surprise Bonus Perks simply for being a Pro Xtra member.

AC Capacitor Replacement (2024)

FAQs

Is it OK to run AC with bad capacitor? ›

Can My Air Conditioner Run on a Bad Capacitor? Over time, the capacitor can become corroded or damaged, which can prevent it from working properly. While your HVAC system may still run, it's not wise to continue using the cooling cycle until an AC capacitor replacement is installed.

Can I use a 2.0 uf capacitor to replace a 1.5 uf capacitor? ›

Yes, provided the voltage rating is the same or higher And it's of the same type!

What are the two typical signs that a capacitor is bad or has failed? ›

Signs of a Bad AC Capacitor

Some common symptoms include strange noises coming out from fan motors or compressor units; slow start up time; lack of cooling even after running continuously; flickering lights due to voltage fluctuations etcetera.

How many years does an AC capacitor last? ›

AC capacitors are designed to last for many years, but eventually, they will need to be replaced. On average, an AC capacitor might last between 5-20 years.

Will the condenser fan run if the capacitor is bad? ›

If the start capacitor malfunctions or wears out, it usually prevents the HVAC unit or the blower from turning on. A bad run capacitor won't prevent the unit from starting, but it can lead to the unit shutting down prematurely, overheating, or making more noise than usual.

How do I tell if my AC capacitor is bad? ›

Most common first signs of a bad AC capacitor:
  1. Vents Not Blowing Cold Air. ...
  2. Higher Than Usual Energy Bills. ...
  3. Unusual Compressor Humming Noises. ...
  4. Older HVAC System. ...
  5. Independent Shutdown. ...
  6. Sluggish Turn On and Operation. ...
  7. AC is Inoperable.
Jan 11, 2022

Is it OK to replace a capacitor with higher capacitance? ›

There is a maximum of +10% tolerance in microfarad rating on replacement start capacitors, but exact run capacitors must be replaced. Voltage rating must always be the same or greater than original capacitor whether it is a start or run capacitor.

What happens when I change a 1.5 uf capacitor to a 2uF capacitor in a stand fan because it is very slow? ›

What happens when I change a 1.5uF capacitor to a 2uF capacitor in a stand fan because it is very slow? It won't speed up. The top speed of an induction motor is based on the AC line frequency. So you can slow it down from that by increasing slip of the rotor, but not speed it up above this speed.

How do you tell if it is a start or run capacitor? ›

1) Run capacitors are rated in a range of 3–70 microfarad (uF). Run capacitors are also rated by voltage classification. The voltage classifications are 370V and 440V. Capacitors with ratings above 70 microfarad (uF) are starting capacitors.

Can a bad capacitor ruin a compressor? ›

Although your unit may continue to run, it is not wise to continue using the air conditioner before replacing a failing capacitor as it can lead to compressor failure and fan motor issues as well as system failure.

Why do AC capacitors fail so often? ›

Minor power surges or other fluctuations in power also overload the capacitor and may cause it to fail. Your AC capacitor may also fail if the fan motor burns out or is somehow impeded from spinning freely. The capacitor continues to send power to try and operate the fan but eventually overloads and burns out.

Will a bad AC capacitor trip the breaker? ›

Bad Capacitor

A capacitor is responsible for starting the compressor, and if the compressor has trouble starting, it could pull too many amps and trip the breaker. Sometimes capacitors wear out, so they'll need to be replaced. Solution: Contact an AC contractor to replace the bad capacitor.

What is the average cost to replace a AC capacitor? ›

Installing a new AC capacitor usually costs between $80 and $400, including labor, but most homeowners pay around $190. Several factors can affect these costs. For instance, if you live in a particularly hot region with a high demand for AC technicians, you'll likely pay more in labor than in cooler regions.

Should I turn off AC if capacitor is bad? ›

If you keep on running an air conditioner with a bad capacitor, it will further damage and break down your air conditioner. No matter which capacitor your air conditioner holds, if it crumbles, then the engine to which it was fastened will still strive to work.

Can I replace an AC capacitor myself? ›

This is why we advise our clients not to open their unit's door to install a new capacitor without a help of a professional. Since AC capacitors are high-voltage components that might cause significant injury to you even if the power is out, it is strongly recommended against changing them yourself.

Can I run my AC without a capacitor? ›

An air conditioner capacitor is an essential part of an air conditioning system. It provides the electrical charge necessary to run components in your air conditioner unit. This includes parts like the fan motor, blower motor, and air handler.

Will a motor run with a bad run capacitor? ›

A run capacitor is an energy-saving device that is in the motor circuit at all times. If a run capacitor fails, the motor can display a variety of problems including not starting, overheating, and vibrating. A bad run capacitor deprives the motor of the full voltage it needs to operate correctly.

Will a bad capacitor cause AC to short cycle? ›

Bad Capacitors

If the run capacitor is damaged, or if the flow of electricity to it is interrupted, it could shut the system off, only to have it turn on again once the temperature hits a certain point.

Can a bad capacitor cause AC to freeze? ›

The most likely reason your air conditioner coils are icing up is a lack of airflow due to a faulty fan motor capacitor. This part aids the fan in circulating cooled air throughout the room.

References

Top Articles
Latest Posts
Article information

Author: Stevie Stamm

Last Updated:

Views: 5937

Rating: 5 / 5 (60 voted)

Reviews: 83% of readers found this page helpful

Author information

Name: Stevie Stamm

Birthday: 1996-06-22

Address: Apt. 419 4200 Sipes Estate, East Delmerview, WY 05617

Phone: +342332224300

Job: Future Advertising Analyst

Hobby: Leather crafting, Puzzles, Leather crafting, scrapbook, Urban exploration, Cabaret, Skateboarding

Introduction: My name is Stevie Stamm, I am a colorful, sparkling, splendid, vast, open, hilarious, tender person who loves writing and wants to share my knowledge and understanding with you.